Introduction

Capillary pumped loops (CPLs) are thermal management systems that are widely used in various applications such as spacecraft thermal control systems, electronic cooling, and high-powered laser systems. These systems utilize the capillary action of a porous wick to circulate a working fluid and remove heat from a heat source to a heat sink. The design of capillary pumped loops plays a crucial role in determining the overall performance and efficiency of the system.

This thesis aims to investigate and optimize the design of capillary pumped loops for improved thermal management in various applications. The research will focus on the system design, methodology, optimization, and implementation of CPLs to achieve maximum heat transfer efficiency and reliability.

Table of contents

Chapter 1: Introduction
1.1 Introduction
1.2 Background of study
1.3 Problem Statement
1.4 Objective of study
1.5 Limitation of study
1.6 Scope of study
1.7 Significance of study
1.8 Structure of the Thesis
1.9 Definition of terms

Chapter 2: Literature Review
2.1 Overview of capillary pumped loops
2.2 Historical development of CPLs
2.3 Working principles of CPLs
2.4 Applications of CPLs
2.5 Current challenges in CPL design
2.6 Previous research on CPL design
2.7 Materials and wick structures for CPLs
2.8 Heat transfer mechanisms in CPLs
2.9 Optimization techniques for CPL design
2.10 Summary of literature review

Chapter 3: System Design and Methodology
3.1 System requirements and specifications
3.2 Selection of working fluid
3.3 Design considerations for wick structure
3.4 Sizing and optimization of evaporator and condenser
3.5 Thermal analysis and modeling
3.6 Experimental setup and methodology
3.7 Test procedures and data collection
3.8 Performance evaluation metrics
3.9 Data analysis and interpretation

Chapter 4: System Implementation
4.1 Design and fabrication of CPL prototype
4.2 Integration of components
4.3 Testing and validation of CPL system
4.4 Performance testing under various operating conditions
4.5 Optimization and fine-tuning of system parameters
4.6 Comparison with theoretical models
4.7 Reliability and stability analysis
4.8 Failure modes and mitigation strategies

Chapter 5: Conclusion and Summary
5.1 Summary of research findings
5.2 Achievements and contributions
5.3 Recommendations for future research
5.4 Conclusion

Thesis Overview

The design of capillary pumped loops is a critical aspect of thermal management systems, with applications ranging from spacecraft to electronic cooling. This thesis focuses on investigating and optimizing the design of CPLs to enhance their performance and efficiency. The research will involve a comprehensive literature review, system design and methodology, system implementation, and conclusion and summary of the project.

In Chapter 1, the introduction provides an overview of the research topic, background, problem statement, objectives, limitations, scope, significance, and structure of the thesis. Chapter 2 presents a detailed literature review on CPLs, including historical development, working principles, applications, challenges, materials, heat transfer mechanisms, and optimization techniques.

Chapter 3 discusses the system design and methodology, covering system requirements, working fluid selection, wick structure design, sizing of components, thermal analysis, experimental setup, and performance evaluation. Chapter 4 focuses on system implementation, including the fabrication of a CPL prototype, integration of components, testing, optimization, and reliability analysis.

Finally, Chapter 5 concludes the thesis with a summary of research findings, achievements, recommendations for future research, and a conclusion. The thesis aims to provide valuable insights into the design and optimization of capillary pumped loops for enhanced thermal management in various applications.

[ad_2]


Purchase Detail

Download the complete project materials to this project with Abstract, Chapters 1 – 5, References and Appendix (Questionaire, Charts, etc), Click Here to place an order via whatsapp. Got question or enquiry; Click here to chat us up via Whatsapp.
You can also call 08111770269 or +2348059541956 to place an order or use the whatsapp button below to chat us up.
Bank details are stated below.

Bank: UBA
Account No: 1021412898
Account Name: Starnet Innovations Limited

The Blazingprojects Mobile App



Download and install the Blazingprojects Mobile App from Google Play to enjoy over 50,000 project topics and materials from 73 departments, completely offline (no internet needed) with monthly update to topics, click here to install.

Read Previous

Genetic engineering of plants for increased steviol glycoside production – Complete Phd and Masters Thesis

Read Next

Sea level rise impacts on coastal aquifers – Complete Phd and Masters Thesis

Leave a Reply

Your email address will not be published. Required fields are marked *

Translate »